CVV 0.6/1KV Control Cable
Conductor: Concentric Stranded copper wire
Cores: 2-30 core
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.
7 Core CVV Control Cable Parameter Data
sectional area | No.& dia. | Thickness | Thickness | Overall diameter (Approx.) | Cable | Standard Length |
of wires | of insulation | of sheath | weight (Approx.) | |||
mm2 | No./mm | mm | mm | mm | kg/km | m |
0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 170 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13 | 200 | 500/D |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 215 | 500/D |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 270 | 500/D |
2.5 | 7/0.67 | 0.8 | 1.8 | 16 | 380 | 500/D |
4 | 7/0.85 | 1 | 1.8 | 19.5 | 570 | 500/D |
6 | 7/1.04 | 1 | 1.8 | 21 | 795 | 500/D |
CVV-S 0.6/1KV Control Cable 60502 Standard
Conductor: Concentric Stranded copper wire
Core: 2-15 cores
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Shield: Annealed copper tape
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches
5 Core CVV-S Control Cable Parameter Detail Data
Nominal cross-sectional area | No.& dia. of wires | Thickness of insulation | Thickness of inner sheath | Thickness of outer sheath | Overall diameter (Approx.) | Maximum conductor resistance | Cable weight |
mm2 | No./mm | mm | mm | mm | mm | (at20C) Ohm/km | (Approx.) kg/km |
0.5 | 7/0.30 | 0.8 | 1 | 1.8 | 14.5 | 36 | 250 |
0.75 | 7/0.37 | 0.8 | 1 | 1.8 | 15 | 24.5 | 280 |
1 | 7/0.40 | 0.8 | 1 | 1.8 | 15.5 | 18.1 | 295 |
1.5 | 7/0.50 | 0.8 | 1 | 1.8 | 16.5 | 12.1 | 345 |
2.5 | 7/0.67 | 0.8 | 1 | 1.8 | 18 | 7.41 | 445 |
4 | 7/0.85 | 1 | 1 | 1.8 | 20.5 | 4.61 | 620 |
6 | 7/1.04 | 1 | 1 | 1.8 | 22.5 | 3.08 | 780 |
CVV-SWA 0.6/1KV Control Cable
Conductor: Concentric Stranded annealed copper wire
Insulation: PVC Black color
Core: 2-30 Core
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Armour: Galvanized steel wire
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For use in duct, tray and for direct burying in ground. The cable subjects to immerse in water all the line.
Nominal cross-sectional area | No.&dia.of wires | Thickness of insulation | Thickness of inner sheath | Diameter of steel wire armour | Thickness of outer sheath | Overall diameter (Approx.) | Maximum conductor (at20C) | Cable weight (Approx.) |
mm2 | No./mm | mm | mm | mm | mm | mm | Ohm/km | kg/km |
0.5 | 7/0.30 | 0.8 | 1.2 | 0.8 | 1.8 | 16.5 | 36 | 380 |
0.75 | 7/0.37 | 0.8 | 1.2 | 0.8 | 1.8 | 17 | 24.5 | 410 |
1 | 7/0.40 | 0.8 | 1.2 | 0.8 | 1.8 | 17 | 18.1 | 425 |
1.5 | 7/0.50 | 0.8 | 1.2 | 0.8 | 1.8 | 18 | 12.1 | 480 |
2.5 | 7/0.67 | 0.8 | 1.2 | 1.25 | 1.8 | 20.5 | 7.41 | 715 |
4 | 7/0.85 | 1 | 1.2 | 1.25 | 1.8 | 23 | 4.61 | 915 |
6 | 7/1.04 | 1 | 1.2 | 1.25 | 1.8 | 24.5 | 3.08 | 1075 |