2-2-2-4 Aluminum Wire Direct Burial Cable For Sale
ABC Cable NFC Standard
The ABC cable NFC standard refers to a specific type of overhead power distribution cable that is commonly used in many countries, particularly in Europe and Africa.
Share
Phase Conductor
Class 2 Circular compacted stranded Aluminium
Neutral Conductor
Class 2 Circular compacted stranded Aluminium
Insulation
XLPE (Cross-linked polyethylene) UV Resistant
ABC cable (Aerial Bundled Cable) NFC standard is used for overhead power distribution in low voltage (LV) networks.
It for overhead power distribution, residential areas, rural electrification, street lighting, and industrial and commercial applications.
The advantages of ABC cables include their reliability, safety, and cost-effectiveness. They are also easy to install and require less maintenance than traditional power distribution systems.
NFC 33-209 Standard.
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
No.x mm^2 | mm | Kg/Km | Ω/Km | KN | A |
2×10 RM | 12.8 | 93 | 3.08 | 1.5 | 38 |
4×10 RM | 15.4 | 183 | 3.08 | 1.5 | 38 |
2×16 RM | 14.8 | 129 | 1.91 | 2.3 | 72 |
2×16 RN + 2×1.5 RE | 14.8 | 176 | 1.910/12.100 | 2.3 | 72 |
4×16 RM | 17.8 | 257 | 1.91 | 2.3 | 72 |
4×16 RN + 2×1.5 RE | 17.8 | 304 | 1.910/12.100 | 2.3 | 72 |
2×25 RM | 18 | 202 | 1.2 | 3.8 | 107 |
2×25 RM + 2×1.5 RE | 18 | 249 | 1.200/12.100 | 3.8 | 107 |
4×25 RM | 21.7 | 404 | 1.2 | 3.8 | 107 |
4×25 RM + 2×1.5 RE | 21.7 | 451 | 1.200/12.100 | 3.8 | 107 |
2×35 RM | 20.8 | 269 | 0.868 | 5.2 | 132 |
2×35 RM + 2×1.5 RE | 20.8 | 316 | 0.868/12.100 | 5.2 | 132 |
4×35 RM | 25.1 | 539 | 0.868 | 5.2 | 132 |
4×35 RM + 2×1.5 RE | 25.1 | 586 | 0.868/12.100 | 5.2 | 132 |
2×50 RM | 23.4 | 352 | 0.641 | 7.6 | 165 |
2×50 RM + 2×1.5 RE | 23.4 | 399 | 0.641/12.100 | 7.6 | 165 |
1×54.6 RM + 3×25 RM | 21.7 | 507 | 0.630/1.200 | 3.8 | 107 |
1×54.6 RM + 3×25 RM + 1×16 RM | 24.3 | 573 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 2×16 RM | 29.7 | 639 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 3×16 RM | 31.1 | 705 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×35 RM | 25.1 | 615 | 0.630/0.868 | 5.2 | 132 |
1×54.6 RM + 3×35 RM + 1×16 RM | 28.1 | 680 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 2×16 RM | 34.3 | 748 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 3×16 RM | 35.9 | 814 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 1×25 RM | 28.1 | 714 | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 |
1×54.6 RM + 3×50 RM | 28.2 | 741 | 0.630/0.641 | 7.6 | 165 |
1×54.6 RM + 3×50 RM + 1×16 RM | 31.6 | 806 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 2×16 RM | 38.6 | 875 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 3×16 RM | 40.4 | 940 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 1×25 RM | 31.6 | 841 | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 |
1×54.6 RM + 3×70 RM | 33 | 950 | 0.630/0.443 | 10.2 | 205 |
1×54.6 RM + 3×70 RM + 1×16 RM | 37 | 1014 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 2×16 RM | 45.2 | 1083 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 3×16 RM | 47.3 | 1148 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 1×25 RM | 37 | 1048 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 2×25 RM | 45.2 | 1150 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 3×25 RM | 47.3 | 1250 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×95 RM | 37.4 | 1176 | 0.630/0.320 | 13.5 | 240 |
1×54.6 RM + 3×95 RM + 1×16 RM | 41.9 | 1243 | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 |
Manufacturing Process
Conductor Stranding
Extruded Insulation
Cabling
Armoured
Extruded Outer Sheath
Packing On Drum