Avada Classic Shop
Sales@hlcables.com
+86-15093102503
Leave a Message
Loading...

Load Bearable Detecting-Well Logging Cable

Conductor:  composed of copper conductors, insulating plastic and steel wire armor.
Cores of number:  single core, three core, four core, seven core, etc..
Nominal size of diameter: is divided into: 4.70mm, 3.5mm, 5.60mm, 6.40mm, 8.00mm, 11.8mm, 12.60mm, 13.20mm.
Working temperature:  heat grade is divided into: room temperature cable (-30~150 C), high-temperature cable (-50~260 C).
Shielding: total shielding and split phase Shielding plus total shielding.
Corrosion grade is divided into: ordinary steel and hydrogen sulfide type anti fal

Characteristics and use

For various types of oil, gas well logging, perforation, coring and other operations, can also be used for marine survey, river, harbor. The connection line between the ground system and the underground instrument is used as the link between the ground system and the underground instrument as the link between ground system and the underground instrument.

7/32” (5.69 mm) 5/16″ (8.18 mm) 9/32” (7.32 mm) monoconductor well logging cable

7/32” (5.69 mm) Monoconductor

Cable Diameter: 0.224” +0.005” – 0.002” (5.69mm +0.13mm -0.05mm)
Minimum Sheave Diameter: 14” (36cm)
Cable Stretch Coefficient: 2.2 ft/kft/Klbs (2.5 m/Km/5KN)
Maximum Conductor Voltage: 1,200 VDC
Conductor AWG Rating: 16
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 Mega Ω/Km @ 1000VDC)
Armor Electrical Resistance: 4.3 Ω/Kft (14.1 Ω/Km)

5/16″ (8.18 mm) Monoconductor

Cable Diameter: 0.322″ +0.005″ – 0.002″ (8.18 mm +0.13 mm -0.05mm)
Minimum Sheave Diameter: 18″ (46 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)
Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1,000 VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

9/32” (7.32 mm) Monoconductor

Cable Diameter: 0.288” +0.005” – 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 16” (41 cm)
Cable Stretch Coefficient: 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)
Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 2.8 Ω/Kft (9.2 Ω/Km)

The parameter data

7/32” (8.18 mm) Monoconductor

Core Description Cable Weight
Temp Rating Plastic Type Insulation Thickness Copper Construction Res Typical O.D. Each In Air In H2O
°F in in Ω/Kft in lbs/Kft
°C mm mm Ω/Km mm Kg/Km
300* Poly 0.042 19×0.0142 2.8 0.155 187 155
149* 1.067 19×0.361 9.2 3.937 278 230

7/32” (5.69 mm) Monoconductor

300* Poly 0.0245 19×0.0119 4.1 60 0.108 91
149* 0.622 19×0.302 13.5 197 2.743 136
420* ETFE 0.0115 19×0.0119 4.1 61 0.108 92
216* 0.292 19×0.302 13.5 200 2.743 137

7/32” (7.32 mm) Monoconductor

500* ETFE 0.019 19×0.0142 2.8 50 0.136 157
260* 0.483 19×0.361 9.2 180 3.454 234
500* FEP 0.0135 19×0.0142 2.8 50 0.098 157
260* 0.343 19×0.361 9.2 180 2.489 234
300* Poly 0.0325 19×0.0142 2.8 56 0.136 152
149* 0.826 19×0.361 9.2 184 3.454 226

Maybe You Like Following Products